Gamma-genes effects of the copper in the 18Cr8Ni stainless steels

Authors

  • J. Botella Acerinox, S.A. Centro de Investigaciones y Ensayos
  • P. Hierro Dpto. de Ciencias de los Materiales e Ingeniería Metalúrgica. Facultad de Ciencias Químicas. Universidad Complutense
  • C. Merino Dpto. de Ciencias de los Materiales e Ingeniería Metalúrgica. Facultad de Ciencias Químicas. Universidad Complutense

DOI:

https://doi.org/10.3989/revmetalm.1997.v33.i5.841

Keywords:

Austenitic stainless steels, δ-ferrite, Nickel equivalent of the copper

Abstract


From a series of 22 typical 18Cr8Ni stainless steel 40 kg ingots, with copper variable concentrations from 0.6 to 3.0 weight %, δ-ferrite is measured with a ferrite-meter device, calculating a nickel equivalent of 0.27 for copper. Some differences between the 8-ferrite and that on calculated by DeLong -excluding the copper γ-gene action- have been found because of different solidification and cooling regimes in ingot and weld cases.

Downloads

Download data is not yet available.

Downloads

Published

1997-10-30

How to Cite

Botella, J., Hierro, P., & Merino, C. (1997). Gamma-genes effects of the copper in the 18Cr8Ni stainless steels. Revista De Metalurgia, 33(5), 298–303. https://doi.org/10.3989/revmetalm.1997.v33.i5.841