Spatial resolution in laser ablation inductively coupled plasma mass spectrometry
DOI:
https://doi.org/10.3989/revmetalm.0915Keywords:
Laser ablation, Inductively coupled plasma mass spectrometry, Spatial resolution, Welded samples, Coated metal samplesAbstract
Laser ablation as sampling system in inductively coupled plasma mass spectrometry (LA-ICP-MS) offers the possibility to know the spatial distribution of elements present in a solid sample. By varying the position of the laser beam on the sample surface, the profile of the lateral distribution of elements is obtained and, with successive pulses fired on a fixed point, profile in depth is achieved. After optimization of operating parameters the technique has been applied to samples with different compositions in both surface and depth.With regard to the lateral resolution has been found that in a length similar to the crater diameter of the laser beam, the signals of the elements appear mixed, making difficult to accurately establish the interface. Regarding the resolution in depth is clearly established the influence of the natural abundance of the measured isotopes.
Downloads
References
[1] K. Niemax, Fresenius J. Anal. Chem. 370 (2001) 332-340. doi:10.1007/s002160100796 PMid:11495052
[2] D. Günther, S.E. Jackson y H.P. Longerich, Spectrochim. Acta Part B 54 (1999) 381-409. doi:10.1016/S0584-8547(99)00011-7
[3] J.J. González, A. Fernández, X. Maoa y R.E. Russo, Spectrochim. Acta Part B 59 (2004) 369-374. doi:10.1016/j.sab.2003.12.021
[4] I. Kroslakova y D. Günther, J. Anal. Atom. Spectrom. 22 (2007) 51-62. doi:10.1039/b606522h
[5] B. Fernández, F. Claverie, C. Pécheyran, O.F.X. Donard, Trends Anal. Chem. 26 (2007) 951-966. doi:10.1016/j.trac.2007.08.008
[6] A. Plotnikov, C. Vogt, K.Wetzig y A. Kyriakopoulos, Spectrochim. Acta Part B 63 (2008) 474-483. doi:10.1016/j.sab.2007.12.012
[7] L.I.L. Balcaen, J. Lenaerts, L. Moens y F. Vanhaeke, J. Anal. Atom. Spectrom. 20 (2005) 417-423. doi:10.1039/b412287a
[8] D. Bleiner, P. Lieneman, A. Ulrich, H. Vonmont y A. Wichser, J. Anal. Atom. Spectrom. 18 (2003) 1.146-1.153.
[9] C. Dubuisson, A.G. Cox, C.W. Mcleod, I. Whiteside, R. Jowit y H. Falk, ISIJ Int. 44 (2004) 1.859-1.866.
[10] S. Nafisi, R. Cox y R. Ghomashchi, J. Alloy. Compd. 415 (2006) 99-105.
[11] A.V. Karasev, R. Inoue y H. Suito, ISIJ Int. 41 (2001) 757-765. doi:10.2355/isijinternational.41.757
[12] A.V. Karasev, y H. Suito, ISIJ Int. 44 (2004) 356-363. doi:10.2355/isijinternational.44.356
[13] J. Pisonero, I. Kroslakova, D. Günther y C. Latkoczy, Anal. Bioanal. Chem. 386 (2006) 12-20. doi:10.1007/s00216-006-0658-0 PMid:16906387
[14] C. Latkoczy y T. Ghislain, J. Anal. Atom. Spectrom. 21 (2006) 1.152-1.160.
[15] A.G. Coedo, T. Dorado, I. Padilla y J.C. Fariñas, Talanta 71 (2007) 2.108-2.120.
[16] A.G. Coedo, T. Dorado, I. Padilla y R. Usero, ISIJ Int. 48 (2008) 194-199. doi:10.2355/isijinternational.48.194
[17] A. Plotnikov, C. Vogt, V. Hoffmann, C. Täschner y K.Wetzig, J. Anal. Atom. Spectrom. 16 (2001) 1.290-1.295.
[18] D. Bleiner, A. Plotnikov, C. Vogt, K.Wetzig y D. Günther, Fresenius J. Anal. Chem., 368 (2000) 221-226. doi:10.1007/s002160000417 PMid:11220583
[19] V.Kanicky, H.R. Kuhn y D. Günther, Anal. Bioanal. Chem. 380 (2004) 218-226. doi:10.1007/s00216-004-2698-7 PMid:15551076
[20] A.G. Coedo, T. Dorado, I. Padilla y J.C. Fariñas, J. Anal. Atom. Spectrom. 20 (2005) 612-620. doi:10.1039/b504114g
[21] A.V.Izmer, M.V.Zoriy, C. Pickhardt, W. Quadakkers, V. Shemet, L. Singheiser y J.S. Becker, J. Anal. Atom. Spectrom. 20 (2005) 918-923. doi:10.1039/b505459c
[22] A. Hrdlicka, V. Otruba, K. Novotny, D. Hünther y V. Kanicky, Spectrochim. Acta, Part B 31 (2005) 307-318. doi:10.1016/j.sab.2005.02.001
[23] I. Lieve, L. Balcaen, J. Lenaerts, L. Moensy y F. Vanhaecke, J. Anal. Atom. Spectrom. 20 (2005) 417-423. doi:10.1039/b412287a
[24] M.P.Mateo, C.C. García y R. Hergenröder, Anal. Chem. 79 (2007) 4.908-4.914.
[25] G. Sarah, B. Gratuze y J.N. Barrandon, J. Anal. Atom. Spectrom. 22 (2007) 1.163-1.167.
[26] S. Hofmann, Surf. Interface Anal. 27 (1999) 825-834. doi:10.1002/(SICI)1096-9918(199909)27:9<825::AID-SIA638>3.0.CO;2-D
[27] M.P.Mateo, J.M. Vadillo y J.J. Laserna, J. Anal. Atom. Spectrom. 16 (2001) 1.317-1.321.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2010 Consejo Superior de Investigaciones Científicas (CSIC)

This work is licensed under a Creative Commons Attribution 4.0 International License.
© CSIC. Manuscripts published in both the printed and online versions of this Journal are the property of Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.All contents of this electronic edition, except where otherwise noted, are distributed under a “Creative Commons Attribution 4.0 International” (CC BY 4.0) License. You may read here the basic information and the legal text of the license. The indication of the CC BY 4.0 License must be expressly stated in this way when necessary.
Self-archiving in repositories, personal webpages or similar, of any version other than the published by the Editor, is not allowed.