Comparison between TTS diagrams obtained by Huey and modified Strauss standard tests for AISI 304 stainless steel
DOI:
https://doi.org/10.3989/revmetalm.1996.v32.i2.918Keywords:
Austenitic stainless steel, Intergranular corrosion, Huey test, Modified Strauss test, SensitizationAbstract
This work presents a comparison of Temperature-Time-Sensitization TTS diagrams obtained by Huey and modified Strauss standard, for detecting susceptibility to intergranular attack. The difference between these tests is the use of a strong or a slightly smooth oxidizing electrolyte. The diagrams obtained are different and if a sample tested by modified Strauss is sensitized, then it will be sensitized in the Huey test, but the contrary is not always true. This difference is because a sensitized sample has to have a continuous band lacking in chromium along the grain boundary in order to be sensitized in the modified Strauss test. This condition is not necessary in the Huey test.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 1996 Consejo Superior de Investigaciones Científicas (CSIC)

This work is licensed under a Creative Commons Attribution 4.0 International License.
© CSIC. Manuscripts published in both the printed and online versions of this Journal are the property of Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.
All contents of this electronic edition, except where otherwise noted, are distributed under a “Creative Commons Attribution 4.0 International” (CC BY 4.0) License. You may read the basic information and the legal text of the license. The indication of the CC BY 4.0 License must be expressly stated in this way when necessary.
Self-archiving in repositories, personal webpages or similar, of any version other than the published by the Editor, is not allowed.